How To Fix A Gas Geyser
A practical guide to the most common gas geyser faults - what you can safely check yourself, and when to call a registered installer.
Diagnose the problem first
Before you can fix anything, work out what the geyser is and is not doing. Most new gas geysers are electronic and display an error code; check the manual for what the code means. That tells you whether it is something you can check yourself or a job for a registered installer.
The checks below are the ones we run on callouts. Start with the simple things - gas, power and water flow - before you suspect the unit itself. If you smell gas at any point, stop and read the safety note at the end.
Why is my gas geyser not igniting?
There are four things to check, in this order:
- Gas. Is there enough gas in the bottle, is the regulator working, and are the shut-off valves open? A bottle can feel light and still have enough gas for a few minutes, but a closed valve or a failed regulator will stop gas reaching the burner.
- Power. Most battery-operated geysers use two D cells. Each cell should read about 1.5 V. As the voltage drops, the ignition may still spark but the gas solenoid will not pull open, so no gas is released.
- Flow detection. The geyser only sparks and opens the gas valve when it detects water flow. Low water pressure, a blocked filter, debris in the line or a restriction after the geyser can all reduce the flow enough to stop it from firing.
- Microswitch and safety sensors. Diaphragm-operated geysers need the microswitch to close and send the signal to the controller. A faulty water-temperature or flue-temperature cut-off will also stop the unit from running.
If the simple checks do not fix it, the next step is a gas pressure test and a look at the ignition circuit. Both are jobs for a registered gas installer.
My gas geyser is sparking but not igniting
Sparking is a good sign: the flow detection and ignition circuit are working. The problem is gas. There are three common causes:
- No gas or low gas pressure. Check the bottle and the shut-off valve. If there is pressure before the regulator but none after it, the regulator has failed.
- Regulator pressure creep. A regulator can let pressure build up when the geyser is off. The solenoid in the geyser may not be strong enough to pull its plunger back against that pressure, so no gas gets through.
- Flat batteries. The batteries may have enough power to spark but not enough to pull the solenoid open.
A gas pressure test at the test point will show which of the three it is. Ask your installer to check the reading against the range on the unit's data plate. Do not keep cycling the unit if you smell gas.
What gas pressure should my geyser run at?
The exact figure is on the data plate of the geyser, together with the operating pressure. As a general guide, the static and operating pressure should not exceed 2.8 kPa. Do not adjust the regulator to guess at a setting; the pressure has to be measured with a manometer at the test point and checked against the data plate.
Why is my gas geyser not igniting after a gas refill?
This is usually an air lock. When the bottle is disconnected, air gets into the line. That pocket of air blocks the gas from reaching the geyser, so the unit sparks but does not light.
- Immediately after changing the cylinder, run the geyser for a minute or two to push the air through. If the system sits, the air and gas separate further and the problem gets worse.
- Ask your installer to fit a shut-off valve just outside the gas cage or just after the regulator. That limits how much air can get into the line when the bottle is disconnected.
- Cycle the geyser on and off until the gas reaches it.
- If it still will not light, call an installer to purge the line safely.
Bleeding the gas line is not a DIY job. We have seen geysers damaged by customers bleeding gas and not reconnecting the test point properly. If you smell gas, turn the cylinder off, open the windows (if the unit is indoors or enclosed) and call us.
Can I bleed air out of the gas line myself?
No. Bleeding the line sounds simple, but it is not a DIY job. Many gas geysers have been burned out by owners who did not know how to do it safely. The line has to be purged at the test point, the test point has to be sealed properly afterwards, and the connection has to be leak tested. If you have just changed a cylinder and the geyser will not light, follow the steps in the refill section above: run the geyser for a minute or two, cycle the tap, and call a registered installer if it still will not light.
Why is my gas geyser not igniting after load-shedding?
Fan-forced geysers with a wired remote sometimes do not switch themselves back on when the power returns. They are waiting for a command, so the fix is simply to turn the geyser on at the remote. If the remote is on and the unit still does not fire, check the power supply and the error code, then call a registered installer.
Why is my gas geyser not igniting with low water pressure?
Diaphragm-operated geysers need enough water pressure to move the diaphragm and trigger the ignition. If the pressure is too low, the unit thinks no hot tap is open and does nothing. Geysers with a flow sensor can also fail to fire when the flow is too low, or when the sensor itself is faulty. Check that the water is actually flowing at the hot tap and clean the filter. If the flow is normal and the unit still does not fire, the flow sensor needs testing.
Why does my gas geyser ignite and then shut off?
This is less common, and it usually comes down to one of three things:
- Not enough water flow after the initial ignition. There is a surge of flow and pressure that lights the geyser, then the flow drops off and the unit turns itself off.
- A nearly empty or very cold cylinder. The liquid LPG is not evaporating fast enough to sustain the load. There is enough pressure to ignite, but not enough to keep the burner running.
- Another tap opened elsewhere in the house. That takes flow and pressure away from the geyser, and the unit shuts down.
Check the flow at the hot tap and the weight of the cylinder first. If the flow is steady and the bottle is full, the gas pressure needs testing.
Why do I see a pilot flame but the burner does not light?
This is usually a flame rectification (flame detection) fault. The geyser sends gas and a spark to the pilot flame, then looks for a small current through the flame. Once it detects that current, it opens the main burner. A dirty burner, a broken earth wire or a faulty sensor breaks the signal, so the main burner never opens.
This is not a DIY repair. The burner and the controller need to be tested by a registered gas installer.
Why is my gas geyser not producing hot water at all?
If the geyser is lit but the water is cold, the problem is usually on the water side, not the gas side. A plumbing cross-connection between the hot and cold lines can let cold water into the hot line. The geyser may also be set too low to make a difference; adjust the flame height and the water flow. Less flow and a higher flame give hotter water.
If the unit is not lit at all, go back to the not-igniting checks above.
Why is my hot water not hot enough?
On natural draft geysers with a flow and flame-height setting, the unit has to be adjusted to the temperature you want. If it is already set correctly, low gas pressure or a nearly empty cylinder is the next thing to check. A gas line that is undersized or a regulator that is too small will also give lukewarm water, especially in winter.
Our guide to what size gas geyser you need explains the flow and temperature ratings, and which gas geyser is best for a bathroom covers the natural draft and fan-forced differences.
Why is my gas geyser not heating enough water?
A gas geyser heats water by a maximum of 25 °C at its rated flow. For example, 10 °C incoming water comes out at about 35 °C at the rated litres per minute. If your unit is not achieving that, the heat exchanger may be dirty, or there may be a problem with the installation: a blocked flue, a restricted gas supply, or a gas line that is too small. A dirty heat exchanger transfers less heat and can soot up, so it needs to be cleaned or replaced by a registered installer.
Why is my gas geyser leaking water?
There are three common causes:
- The heat exchanger has burst. This is often frost damage after a cold night. A heat exchanger can be replaced; on an old unit a replacement may not be worth it, and we will tell you.
- The water diaphragm assembly is broken. It needs to be replaced.
- Condensate. LPG is a mix of propane and butane. Burning it produces water vapour, and on a fan-forced unit that vapour can condense and drip, which looks like a leak.
If the leak is from a fitting or the pipework, it may just need tightening. If it is from the heat exchanger, stop using the unit and call us.
Why is my gas geyser making a ticking noise?
That is the geyser's ignition system. It should only tick when the unit is trying to light. If it ticks when no hot tap is open, the flow switch or the controller is faulty and the unit needs attention.
If it ticks while the tap is open but does not light, see the not-igniting section above.
Why is my gas geyser cutting out when another tap is opened?
Diaphragm-operated geysers need a pressure difference between the water going in and the water coming out. Opening another tap reduces the flow through the geyser and the pressure difference, so the diaphragm returns to its neutral position and the unit cuts out. Low water pressure or a restriction in the line makes it worse.
A fan-forced unit with a flow sensor is less likely to do this, but it can still cut out if the flow drops below its minimum.
Why is my gas geyser flame yellow or sooty?
A yellow, sooty flame means the burner is not getting enough air, or the flue or heat exchanger is blocked. The soot builds up on the heat exchanger, so it transfers less heat, and the hot spots can burn holes in the heat exchanger wall. Stop using the geyser and call a registered installer to clean the burner and flue and check the heat exchanger.
Huge flames are coming out of my geyser
Huge flames usually mean the regulator has failed. Turn the gas off at the cylinder and do not use the geyser. Call us to replace the regulator and inspect the unit; the excess pressure can damage the gas valve, and the geyser needs to be checked before it is used again.
When to stop and call a registered installer
You can safely check the gas bottle, the shut-off valve, the batteries, the error code and the water flow at the tap. Anything inside the gas side of the unit - the regulator, the solenoid, the burner, the gas valve, the heat exchanger or the flue - is work for a registered gas installer. South African law (the Occupational Health and Safety Act) does not allow an unauthorised person to work on a gas installation, and a repair that is not pressure tested and leak tested can be dangerous. If you have worked through the checks above and are still stuck, that is the point to call us.
If you smell gas: turn the cylinder off, open windows and doors (if the unit is indoors or enclosed), do not switch anything on or off, and call us on 083 592 5450.
We repair and service gas geysers across Boksburg and the East Rand, including Atlas, Paloma, Rinnai, Bosch, Dewhot, Delta and Alva. We assess the unit before quoting. See gas geyser repair in Boksburg for what we repair and what a callout involves, or gas geyser installation if a replacement makes more sense. Call 083 592 5450 to book a technician.