Gas geyser and mixer taps

AD

Diagram gas geysers can experience problems (turning off) when they are connected to mixer taps due to increased pressure in the water line after the gas geyser. Zero rate, constant temperature and fan force driven gas geysers do not suffer from these problems because they do not require a pressure differential to detect water flow.

Why do Diagram gas geysers turn off when I use my mixer tap?

Diagram gas geysers only activate when there is a lower water pressure after the geyser (in the hot water piping system). When the tap is opened the diaphragm moves because it receives a positive pressure coming from the cold water inlet, and it moves because there is lower water pressure in the hot water pipes of the geyser (because the tap is relieving the pressure). When the diaphragm has been moved the geyser will activate and heat water. When you close the tap the pressure equalises in the entire water system in accordance with Pascal’s law. at which point the pressure before and after the diaphragm is equal and it returns to its neutral position and turns of the geyser.

So what’s the big deal with mixer taps? the problem with mixer taps is that they can restrict the water flow in the hot water pipe (like when you adjust the tap to use more cold water). When there is a restriction in the line that causes an increase in pressure and can cause the pressure before and after the geyser to be nearly the same and it can turn off the geyser. In simple terms, the geyser is no being used enough and it “thinks” that it should turn itself off.

In reality, any restriction in the line can cause the geyser to turn off, I had one customer complain that her geyser kept turning off while she was in the shower, upon inspection she had concrete in her pipes, a water-saving showerhead and a mixer tap, along with that she had pretty good water pressure so as she adjusted the tap to use more cold water, the geyser turned off. The combination of these things caused the geyser to turn off. anyone of these things alone could have caused the problem so keep that in mind when you use your geyser.

If someone else uses the cold tap it can also cause a pressure drop before the geyser (cold side) which can cause the diagram to return to its neutral state and then turn off the geyser, so if someone flushes the toilet while you are in the shower there is a good chance that the geyser will turn off and you would have to close the tap and reopen it to get hot water again.

What’s the solution?

There are a few things you can do to reduce this happening to you:

  • The very first thing you should do is adjust your geysers settings to get as close to your ideal shower temperature as possible. If you don’t need to add cold water to your shower in the first place then having a mixer tap won’t be a problem.
  • Remove your water-saving showerhead or anything that might restrict the flow of hot water.
  • Remove the mixer tap, simple as that, it’s an extreme solution that might not be possible, but it is a solution.
  • Change the gas geyser, also an extreme solution, but it might be your only option. The following geysers might be the solution: zero-rated gas geysers, fan-forced gas geysers, constant temp gas geysers.
AD
AD
Share this post:

Related Articles

All posts